  1. Info Drivers!
  2.  
  3. MacSign 4.0.3
  4. International Version
  5. August 1994
  6.  
  7. This documents contains information regarding the plotter drivers included in MacSign 4.0 which were not inserted in the user’s guide.
  8.  
  9. Print and read carefully the contents of this document!
  10.  
  11. •HOW TO CONNECT
  12.  
  13. The most important thing when connecting a plotter is making sure that you are using the same parameters both on the plotter and on the Macintosh. If even only one parameter is different the connection will probably fail.
  14.  
  15. -When connecting the plotter with the Macintosh make sure that both are turned off, then connect them. Check below how to choose the right cable for your plotter;
  16. -Turn on the plotter and set the serial communication parameters on it. Please refer to the plotter’s user guide to learn how to use the plotter,
  17. -Open MacSign and choose Plotter Setup. A dialog box will appear, choose the driver needed for your plotter and set the communication parameters as you did on the plotter.
  18.  
  19. • NOTE ON USING ROLAND CAMM-1 PLOTTER
  20.  
  21. Remember to set the plotter in HP-GL emulation (COMMAND MODE 2) and the plotter axes origin at the lower left corner (FREE-Y or ROTATE0 mode). For a detailed description of these procedures refer to the user's guide given with the peripheral.
  22. To connect a Roland CAMM-1 to a Macintosh you can use the cable included in your MacSign. If you have to create your own cable use this pin layout: 
  23.  
  24.    Macintosh Side                Roland Side
  25.    MiniDIN 8 male                DB 25 male
  26.            1                                    5
  27.            2                                   20
  28.            3                                    3
  29.            4                                    7
  30.            5                                    2
  31.  
  32.  
  33. • NOTE ON USING GRAPHTEC PLOTTERS
  34.  
  35. Remember to set the plotter to GP-GL emulation (see DIP-SWITCHES), the software resolution (see DIP-SWITCHES, program step size) and the plotter axes origin at the lower left corner. For a detailed description of these procedures we refer to the user's guide provided with the peripheral.
  36. To connect a Graphtec to Macintosh you can use the connection cable included in your MacSign package or a serial interface cable will have to be made: 
  37.  
  38.    Macintosh Side              Graphtec Side
  39.    MiniDIN 8 male                DB 25 male
  40.            1                                    5
  41.            2                                   20
  42.            3                                    3
  43.            4                                    7
  44.            5                                    2
  45.  
  46.  
  47. • NOTE ON USING SEI PLOTTERS
  48.  
  49. To connect a SEI plotter to MacSign, you need, besides the connection cable which is supplied with the application, also an adapter cable (Canon DB25 female - Canon DB9 male or Canon DB25 female - Canon DB25 male, according the model) that must be expressly required. This adapter must be used only when you connect a SEI plotter, placing it between the standard cable (so you have to use it again) and the SEI plotter. Also, you can use a serial interface cable will have to be made (according the model): 
  50.  
  51.    Macintosh Side                  SEI Side
  52.    MiniDIN 8 male                DB 25 male
  53.            1                                    5
  54.            2                                   20
  55.            3                                    3
  56.            4                                    7
  57.            5                                    2
  58.  
  59.    Macintosh Side                  SEI Side
  60.    MiniDIN 8 male                DB 9 male
  61.            1                                    -
  62.            2                                    5
  63.            3                                    1
  64.            4                                    2
  65.            5                                    9
  66.  
  67.  
  68. • NOTE ON USING DATAFONT PLOTTERS
  69.  
  70. The default Communication parameters usually are: 9600 baud, 8 bit, 2 stop bit, Hardware Handshake and Parity none. These parameters must be set also into the Plotter Setup command dialog box.
  71. To connect DATAFONT plotter to MacSign, you need, besides the connection cable  supplied with the application, also an adapter cable (Canon DB25 female - Canon DB25 male) that must be expressly required. This adapter must be used only when you connect a DATAFONT plotter, placing it between the standard cable (so you have to use it again) and the DATAFONT plotter. Also you can use a serial interface cable will have to be made: 
  72.  
  73.    Macintosh Side             DATAFONT Side
  74.    MiniDIN 8 male                DB 25 male
  75.            1                                    4
  76.            2                                    5
  77.            3                                    2
  78.            4                                    7
  79.            5                                    3
  80.  
  81.  
  82. • NOTE ON USING HOUSTON INSTRUMENT PLOTTERS
  83.  
  84. Remember to set the plotter in DM/PL emulation (for those models, such as i.e. DMP-69C and DMP-100C, that support the HP-GL emulation too) and the addressing resolution. For a detailed description of these procedures we refer to the user's guide provided with the peripheral.
  85. To connect Houston Instrument plotter to MacSign, you need, besides the connection cable supplied with the application, also an adapter cable (Canon DB25 female - Canon DB25 female) that must be expressly required. This adapter must be used only when you connect a Houston Instrument plotter, placing it between the standard cable (so you have to use it again) and the Houston Instrument plotter. Also you can use a serial interface cable will have to be made: 
  86.    
  87. Macintosh Side                  Houston Side
  88.    MiniDIN 8 male                DB 25 female
  89.            1                                    -
  90.            2                                    4
  91.            3                                    3
  92.            4                                    7
  93.            5                                    2
  94.  
  95.  
  96. • NOTE ON USING IOLINE PLOTTERS
  97.  
  98.  
  99. Remember to set the plotter in DM/PL emulation and the addressing resolution. For a detailed description of these procedures we refer to the user's guide provided with the peripheral.
  100. To connect an IOLine plotter to a Macintosh you can use the cable included in your MacSign. If you have to create your own cable use this pin layout: 
  101.    
  102.    Macintosh Side                IOLINE Side
  103.    MiniDIN 8 male                DB 25 male
  104.            1                                    -
  105.            2                                   20
  106.            3                                    3
  107.            4                                    7
  108.            5                                    2
  109.  
  110.  
  111. • NOTE ON USING ARISTO PLOTTERS
  112.  
  113. Remember to configure the plotter as ARISTO emulation (for a detailed description of these procedures we refer to the user's guide provided with the peripheral).
  114. To connect an ARISTO plotter to Macintosh you can use the connection cable supplied with the application or a serial interface cable will have to be made:
  115.    
  116.    Macintosh Side                 Aristo Side
  117.    MiniDIN 8 male                 DB 25 male
  118.            1                                    -
  119.            2                                    20
  120.            3                                    3
  121.            4                                    7
  122.            5                                    2
  123.  
  124.  
  125. • NOTE ON USING MIMAKI PLOTTERS
  126.  
  127. Remember to set the plotter the plotter resolution to 0.025 mm and the plotter axes origin at the lower right corner. For a detailed description of these procedures we refer to the user's guide provided with the peripheral.
  128. To connect Mimaki plotter to MacSign, you can use the cable provided with MacSign or  a serial interface cable will have to be made: 
  129.    
  130.    Macintosh Side               Mimaki Side
  131.    MiniDIN 8 male                DB 25 male
  132.            1                                    5
  133.            2                                   20
  134.            3                                    3
  135.            4                                    7
  136.            5                                    2
  137.  
  138.  
  139. • NOTE ON USING Zünd PLOTTERS
  140.  
  141. To connect Zünd plotter to MacSign, you need, besides the connection cable  supplied with the application, also an adapter cable (Canon DB25 female - Canon DB25 male) that must be expressly required. This adapter must be used only when you connect a Zünd plotter, placing it between the standard cable (so you have to use it again) and the Zünd plotter. Also you can use a serial interface cable will have to be made: 
  142.  
  143.    Macintosh Side                 Zünd Side
  144.    MiniDIN 8 male                DB 25 male
  145.            1                                    5
  146.            2                                    4
  147.            3                                    3
  148.            4                                    7
  149.            5                                    2
  150.